{"id":159,"date":"2013-12-06T14:52:28","date_gmt":"2013-12-06T05:52:28","guid":{"rendered":"https:\/\/www.net-showa.co.jp\/showa\/?page_id=159"},"modified":"2014-01-24T18:25:02","modified_gmt":"2014-01-24T09:25:02","slug":"lubrication-system-chart","status":"publish","type":"page","link":"https:\/\/www.net-showa.co.jp\/en\/lubrication-system-chart\/","title":{"rendered":"Lubrication system chart"},"content":{"rendered":"<p><\/p>\n<h3 class=\"ttlbar bold mgb20\">Lubrication System Selection<\/h3>\n<p class=\"mgb30\">Depending upon the required lubrication system, a compatible pump and distribution equipment must be selected  to enable correct operation to take place. <br \/>Mixing pumps and distribution equipment from different types of systems may cause faults.<br \/>\nBy referring to the chart below, an appropriate lubrication system and components for a specific requirement can be identified. <\/p>\n<h4 class=\"tx16 bold\">SHOWA Lubrication System Chart<\/h4>\n<p class=\"mgb30\">\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-01.png\" alt=\"SHOWA Lubrication System Chart\" width=\"688\" height=\"750\" class=\"alignnone size-full wp-image-1053\" srcset=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-01.png 688w, https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-01-159x174.png 159w, https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-01-321x350.png 321w\" sizes=\"auto, (max-width: 688px) 100vw, 688px\" \/>\n<\/p>\n<h4 class=\"tx16 bold\">Distribution Equipment \/ Applicable Pump Units<\/h4>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\" class=\"table tx_small table_border table_narrow th_bg mgb10\">\n<thead>\n<\/thead>\n<tbody>\n<tr>\n<th align=\"center\">Distribution Equipment<\/th>\n<th width=\"40%\" align=\"center\" nowrap>Description<\/th>\n<th colspan=\"3\" align=\"center\">Application Pump Units<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-02.png\" alt=\"DPB\" width=\"110\" height=\"66\" class=\"alignnone size-full wp-image-1054\" \/><\/td>\n<td width=\"40%\" rowspan=\"4\"> Measures exact amounts of oil to be distributed, which is not affected by pressure or viscosity. <br \/>\nThe Dester plunger will discharge its pre-measured volume of oil by utilizing the direct pressure produced by the pump.<br \/>\nPumps will need to possess a pressure displacement mechanism, enabling the Dester plungers to replenish itself with oil.<\/td>\n<td rowspan=\"7\">Motorized<\/td>\n<td>MLA*W, MLB*W Models<\/td>\n<td rowspan=\"11\">Intermittent<br \/>\n  Type<br \/>\n  +<br \/>\n  Pressure<br \/>\n  Displacement<\/td>\n<\/tr>\n<tr>\n<td>LCA3 Model<\/td>\n<\/tr>\n<tr>\n<td>LCA4 Model<\/td>\n<\/tr>\n<tr>\n<td>LCB3 Model<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-03.png\" alt=\"DSB\" width=\"110\" height=\"82\" class=\"alignnone size-full wp-image-1055\" \/><\/td>\n<td width=\"40%\" rowspan=\"5\"> Measures exact amounts of oil to be distributed, which is not affected by pressure or viscosity. <br \/>\n  The Dester Block will discharge its pre-measured volume of oil by utilizing the pressure produced by the internal spring. <br \/>\n  The DSBs are suited for lower pressure systems, as discharge is induced by a spring and not by the pump&#8217;s discharge pressure. <\/td>\n<td>LCB3 TMS Model<\/td>\n<\/tr>\n<tr>\n<td>LCB4 Model<\/td>\n<\/tr>\n<tr>\n<td>LCB5 Model<\/td>\n<\/tr>\n<tr>\n<td>Pneumatic<\/td>\n<td>HP*W* Model<br \/>\n  (Contact Showa)<\/td>\n<\/tr>\n<tr>\n<td>Manual<\/td>\n<td>LAW* Model<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-04.png\" alt=\"DG\" width=\"110\" height=\"75\" class=\"alignnone size-full wp-image-1056\" \/><\/td>\n<td width=\"40%\" rowspan=\"2\"> The DG piston distributors, will discharge a pre-measured amount of grease, utilizing the pump&#8217;s discharge pressure.<br \/>\nPumps will require a pressure displacement mechanism to enable the DG to replenish itself with grease. <br \/>\nTo be used in conjunction with GD distribution blocks to simplify installation.<\/td>\n<td>Motorized<\/td>\n<td>GPMW30 Model<\/td>\n<\/tr>\n<tr>\n<td>Manual<\/td>\n<td>GPHW01 Model<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-05.png\" alt=\"SG2\" width=\"110\" height=\"60\" class=\"alignnone size-full wp-image-1048\" \/><\/td>\n<td width=\"40%\" rowspan=\"3\"> Measures exact amounts of lubricant to be distributed, which is not affected by pressure or viscosity. <br \/>\nThe Dester G will discharge measured volumes of grease through each port, one after the other in sequence (progressively). <br \/>\nBlocks with differing discharge volumes selectable.<br \/>\nA visual indicator pin or a limit switch option is available.<\/td>\n<td rowspan=\"4\">Motorized<\/td>\n<td>MHG4 Model<\/td>\n<td rowspan=\"6\">Continuous<br \/>\n    Type<br \/>\n    +<br \/>\n    Progressive<br \/>\n    discharge<\/td>\n<\/tr>\n<tr>\n<td>MHG7 Model<\/td>\n<\/tr>\n<tr>\n<td>GPM101 Model<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-06.png\" alt=\"SG6\" width=\"110\" height=\"75\" class=\"alignnone size-full wp-image-1049\" \/><\/td>\n<td width=\"40%\" rowspan=\"3\"> Measures exact amounts of lubricant to be distributed, which is not affected by pressure or viscosity. <br \/>\n  The Dester G will discharge measured volumes of grease through each port, one after the other in sequence (progressively). <br \/>\n  PSG attachments can be attached to combine ports.<br \/>\n  A Visual indicator pin or a limit switch option is available.<\/td>\n<td>GPM102 Model<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Manual<\/td>\n<td>SHG Model<\/td>\n<\/tr>\n<tr>\n<td>GPH Model<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-07.png\" alt=\"Flow Proper Units\" width=\"110\" height=\"65\" class=\"alignnone size-full wp-image-1050\" \/><\/td>\n<td rowspan=\"7\"> The Flow Proper Unit (Meter Unit) will apply flow resistance according to the number displayed on the unit. <br \/>\nOil from the pump unit can be distributed proportionally by applying various levels of resistance at lubrication points.<br \/>\nThe unit is best suited with accumulative pressure type pumps (no pressure displacement mechanisms).<\/td>\n<td rowspan=\"5\">Motorized<\/td>\n<td>YMAS Model<\/td>\n<td rowspan=\"4\">Intermittent<br \/>\n    Accumulative<br \/>\n    Pressure Type<\/td>\n<\/tr>\n<tr>\n<td>SMD Model<\/td>\n<\/tr>\n<tr>\n<td>SSMA Model<\/td>\n<\/tr>\n<tr>\n<td>MY6 Model<\/td>\n<\/tr>\n<tr>\n<td>MV Model<\/td>\n<td>Continuous<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Manual<\/td>\n<td>LD Model<\/td>\n<td rowspan=\"2\">Intermittent<br \/>\n    Accumulative<\/td>\n<\/tr>\n<tr>\n<td>EA &amp; HLA7 Models<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-08.png\" alt=\"Continuous Units\" width=\"110\" height=\"66\" class=\"alignnone size-full wp-image-1051\" \/><\/td>\n<td rowspan=\"5\">The Continuous Unit applies flow resistance according to the number displayed on the unit.<br \/>\n    By applying various levels of resistance at junctions or lubrication points, the lubricant  can be distributed proportionally.<br \/>\n    Unlike the PSS range, these units possess no internal check valves. <\/td>\n<td rowspan=\"3\">Motorized<\/td>\n<td>MLA, MLC, MLD Models<\/td>\n<td rowspan=\"5\">Continuous<br \/>\n    Type<\/td>\n<\/tr>\n<tr>\n<td>MHG4, MHG7 Models<\/td>\n<\/tr>\n<tr>\n<td>GPM101, GPM102 Models<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Manual<\/td>\n<td>SHG Model<\/td>\n<\/tr>\n<tr>\n<td>GPH Model<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.net-showa.co.jp\/showa\/wp-content\/uploads\/2013\/12\/lubrication-en-09.png\" alt=\"VA VB (Check Valve)\" width=\"110\" height=\"100\" class=\"alignnone size-full wp-image-1052\" \/><\/td>\n<td rowspan=\"12\"> Dester Valve distribution junctions possess adjustable flow-rate valves on each port, allowing simple flow adjustments to be performed.<br \/>\nNo replacement or additional parts are required for basic adjustments and modifications in lubrication output, making system design, installation and modifications simple to perform. <br \/>\nVA &amp; VB units are suited for both the intermittent and continuous type resistance systems and can be used in Total Loss or Circulating lubrication systems. <br \/>\n(Please enquire for usage conditions when utilizing the Dester Valves in conjunction with SMD, SSMA or grease pumps)<\/td>\n<td rowspan=\"4\">Motorized<\/td>\n<td>YMAS Model<\/td>\n<td rowspan=\"3\">Intermittent<br \/>\n    Accumulative<br \/>\n    Pressure Type<\/td>\n<\/tr>\n<tr>\n<td>SMD Model<\/td>\n<\/tr>\n<tr>\n<td>SSMA Model<\/td>\n<\/tr>\n<tr>\n<td>MLA, MLC, MLD Models<\/td>\n<td>Continuous<br \/>\n    Type<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Manual<\/td>\n<td>LA Model<\/td>\n<td>Intermittent<br \/>\n    Direct Pressure<\/td>\n<\/tr>\n<tr>\n<td>HLA7 Model<\/td>\n<td rowspan=\"3\">Intermittent<br \/>\n    Accumulative<br \/>\n    Pressure Type<\/td>\n<\/tr>\n<tr>\n<td>LD Model<\/td>\n<\/tr>\n<tr>\n<td>EA Model<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Motorized<\/td>\n<td>MHG4, MHG7 Models<\/td>\n<td rowspan=\"4\">Continuous<br \/>\n    Type<\/td>\n<\/tr>\n<tr>\n<td>GPM101, GPM102 Models<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Manual<\/td>\n<td>SHG Model<\/td>\n<\/tr>\n<tr>\n<td>GPH Model<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Lubrication System Selection Depending upon the required lubrication system, a compatible pump and distributio [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":14,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-159","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.net-showa.co.jp\/en\/wp-json\/wp\/v2\/pages\/159","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.net-showa.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.net-showa.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.net-showa.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.net-showa.co.jp\/en\/wp-json\/wp\/v2\/comments?post=159"}],"version-history":[{"count":5,"href":"https:\/\/www.net-showa.co.jp\/en\/wp-json\/wp\/v2\/pages\/159\/revisions"}],"predecessor-version":[{"id":1057,"href":"https:\/\/www.net-showa.co.jp\/en\/wp-json\/wp\/v2\/pages\/159\/revisions\/1057"}],"wp:attachment":[{"href":"https:\/\/www.net-showa.co.jp\/en\/wp-json\/wp\/v2\/media?parent=159"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}